Bellows Seal Valve

Conval’s Clampseal® Bellows Seal valves provide a zero-emission solution, perfect for situations where traditional packed valves might struggle to contain light gases or hazardous fluids due to potential leakage in the stem/packing seal or stuffing box wall/packing seal zones. The valves can be installed in the pressure boundary zone of nuclear plants to ensure reliable and tight shutoff, emitting zero emissions.

These valves not only ensure environmental compliance but also adhere to all specifications outlined in MSS SP-117. Conval Bellows Seal valves are also designed with a pressure seal bonnet that provides easy access for servicing with no welds to cut or seal rings or gaskets to replace.

Technical Summary

  • 1/2” through 4” (4” Reduced Port)
  • Through ASME Class 2500
  • Available in Angle, Y, or T pattern
  • Pressure-assisted seal bonnet
  • In-line repairable
  • Zero Fugitive Emissions
  • Cobalt free seat and disc options available
  • Options: electric, pneumatic, and hydraulic actuators
  • N Stamp Approved
  • F91 Type 1 and Type 2

Can’t Find A Product? We’ll Find It For you!

Connect with us to discuss your next big project and we’ll recommend the optimal solution for you.

Book a Consultation

  • This field is for validation purposes and should be left unchanged.

Book a Consultation

  • This field is for validation purposes and should be left unchanged.

Find a Solution

  • This field is for validation purposes and should be left unchanged.

Send the Request

  • This field is for validation purposes and should be left unchanged.

Become a Partner

  • This field is for validation purposes and should be left unchanged.

Design a Solution

  • This field is for validation purposes and should be left unchanged.

Find an Industry Solution

  • This field is for validation purposes and should be left unchanged.

Interested in a Career at Armour Valve?

Find Out More

  • Upload Resume/Cover Letter
    Accepted file types: pdf, Max. file size: 50 MB.
  • This field is for validation purposes and should be left unchanged.

Marc Soucy, P.Eng

National Sales Manager

I am a mechanical engineer with 30 years of plant, sales and service experience. I have been on both sides of the desk and can relate with you when issues arise in the plant. You can trust that I won’t recommend a product unless I know that it will do the job for you.

Marc Soucy, P.Eng

Directeur National des Ventes

J’ai un diplôme en génie mécanique avec 30 ans d’expérience dans les usines, les ventes, et le service. J’ai été de chaque côté du bureau et je comprends lorsque des problèmes font surface dans l’usine, l’importance que l’on doit y apporter. Vous pouvez être sûr que je ne recommanderai pas un produit à moins que je sache qu’il convient à votre application.