HORA Regelarmenturen Automatic Pump Recirculation Valve

HORA Regelarmenturen Automatic Pump Recirculation Valve

HORA automatic recirculation valves are service friendly and durable, extending the lifecycle of your centrifugal pump.

HORA recirculation valves are in-line serviceable, reducing maintenance time. A special piston design and control levels minimize impact of system vibration and pulsations for optimal performance. High pressure and low-pressure models available to ensure fit with your application.

Frequently Asked Questions

Find quick answers to some of the most common questions

How does the HORA Automatic Recirculation Valve protect the pump at low flow?

HORA’s Automatic Recirculation Valve automatically opens a dedicated minimum‑flow bypass when mainline flow drops below the pump’s safe operating limit. The valve uses a mechanical flow‑sensing disc that reacts to decreasing flow and opens the bypass without any external signals. This ensures continuous cooling and prevents overheating, cavitation, and dry‑running damage.

Does the HORA Automatic Recirculation Valve require instrumentation or DCS control?

Hora’s Automatic Recirculation Valve is a fully mechanical, self‑acting valve . It does not require flow transmitters, control valves, PLC logic, or DCS integration. All modulation of the bypass line is performed internally by the valve’s mechanical sensing mechanism.

How does the HORA Automatic Recirculation Valve handle high differential pressures in the bypass line?

Hora uses a multi‑stage pressure‑reducing trim in the bypass section. This staged trim reduces pressure in controlled increments, keeping fluid pressure above vapor pressure and preventing cavitation.

What operating conditions commonly cause Automatic Recirculation Valves to fail, and how does HORA address them?

Common ARV failure modes include sticking caused by debris, unstable bypass modulation during transient pump conditions, and cavitation damage in high‑ΔP bypass lines. HORA’s ARV design directly addresses these issues through guided moving elements that prevent disc vibration or jamming, hardened trim materials for erosive service, multi‑stage bypass trim for cavitation control, and a robust mechanical actuation system engineered to respond reliably during rapid flow changes.

Can the HORA Automatic Recirculation Valve be serviced in‑line?

Yes. HORA designs its Automatic Recirculation Valves for full in‑line serviceability. Internal components — including the flow‑sensing disc, spring assembly, and bypass trim — can be accessed and replaced without removing the valve body from the piping. This reduces downtime and simplifies pump‑room maintenance.

Techincal Support

Need help with our products, booking service or training, or accessing IOM manuals?

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Sales Inquiries

Submit a request for quote and lead‑time information for your upcoming project.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Billing Inquiries

For invoice, payment, or account support, our finance team is here to help.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Work With Armour Valve

Interested in a career with Armour Valve? Share your resume with us.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Max. file size: 50 MB.
Drop files here or
Max. file size: 50 MB.

    General Inquiry

    For general enquiries, company information, or media requests, connect with us.

    "*" indicates required fields

    This field is for validation purposes and should be left unchanged.

    Book a Consultation

    • This field is for validation purposes and should be left unchanged.

    Book a Consultation

    • This field is for validation purposes and should be left unchanged.

    Find a Solution

    • This field is for validation purposes and should be left unchanged.

    Send the Request

    • This field is for validation purposes and should be left unchanged.

    Become a Partner

    • This field is for validation purposes and should be left unchanged.

    Design a Solution

    • This field is for validation purposes and should be left unchanged.

    Find an Industry Solution

    • This field is for validation purposes and should be left unchanged.

    Interested in a Career at Armour Valve?

    Find Out More

    • This field is for validation purposes and should be left unchanged.
    • Upload Resume/Cover Letter
      Accepted file types: pdf, Max. file size: 50 MB.

    Marc Soucy, P.Eng

    National Sales Manager

    I am a mechanical engineer with 35+ years of experience in plant operations, maintenance, and technical sales. As National Sales Manager I bring deep expertise in the power industry and specialty valve market. Having worked on both sides of the desk, I understand the challenges plant teams face. You can trust that I won’t recommend a product unless I know that it will do the job for you.

    Marc Soucy, P.Eng

    Directeur National des Ventes

    Je suis ingénieur en mécanique et possède plus de 35 ans d'expérience en exploitation, maintenance et ventes techniques industrielles. En tant que directeur national des ventes, j'apporte une expertise approfondie du secteur de l'énergie et du marché des vannes spécialisées. Ayant travaillé sur ces deux fronts, je comprends les défis auxquels sont confrontées les équipes d'usine. Soyez assuré que je ne recommanderai aucun produit sans être certain qu'il répondra à vos besoins.